0972064
喬智生技-實驗室規劃,實驗室耗材批發,台中實驗室規劃,台中實驗室耗材批發
店家商品
DESCRIPTION
The FLUOM-5B benchtop fluorometer is easy to operate, combined with a highly sensitive quantitative analysis kit, to accurately quantify DNA, RNA and protein concentrations. And it is equipped with two channels and has the ability to quickly analyze two fluorescent signals of one sample, which is economical!
The combination of the SP-MUV1000 Micro-Volume Spectrophotometer and the FLUOM-5B Fluorometer provides comprehensive, accurate, easy and fast quantification of biomolecules.
Product features
Fluorometers are especially suitable for:
PRODUCT DETAILS
SPECIFICATIONS
Performance index
light source | LED |
Dynamic range | 5 orders of magnitude |
Repeatability | <1.5% |
stability | <1.5% |
Linearity | R2>0.995 |
Sensitivity | dsDNA:0.5ng/ml |
Measuring speed | <3s(Master single test) |
Packaging Size | 440*270*160mm |
Net/ Gross Weight | 2/ 2.5 kg |
Standard configuration: channel
Channel | Excitation wavelength | Emission wavelength |
Blue | 470nm | 525nm |
RED | 625nm | 690nm |
Optional channel
Channel | Excitation wavelength | Emission wavelength |
UV | 365nm | 460nm |
GREEN | 525nm | 620nm |
Commonly used fluorescent reagents corresponding to different fluorescent channels and their applications
Excitation wavelength | Common fluorescent reagents | Application |
365 | Hoechst33258, 4-MU,EnZCheK Caspase | Plant GUS reporter gene assay, cell apoptosis assay |
470 | PicoGreen®, oligreen,RiboGreen®, GFP, Protein, Quant-iT™ | dsDNA, ssDNA quantification, green fluorescent protein GFP, protein quantification |
525 | Rhodamine, Cy3, RFP Vybrant Cytotoxicity | Rhodamine detection, Cy-3 fluorescent label detection, red fluorescent protein RFP gene detection, cell activity toxicity detection |
625 | Cy5, Quant-iT RNA | Cy-5 fluorescent labeling detection, RNA quantification |
Advantages:
Fluorometer-binding quantitative kits use fluorescent dyes to selectively bind to specific target molecules.These fluorescent dyes emit fluorescent signals only when the target molecule is bound.Therefore, it is more accurate than the traditional UV absorption method (SP-MUV1000), because the UV absorption method is not selective and measures the absorption value of all substances at 260 – such as DNA, RNA, protein, degrade nucleic acids and free nucleotides or excess salt ions, etc.In addition, the UV spectrophotometer is not sensitive enough to accurately quantify DNA and RNA at low concentrations (below 2ng/μL), so a highly sensitive fluorometer becomes a better choice. Combined with the corresponding quantitative kit, the FLUOM-5B Fluorometer can quickly, sensitively and accurately determine the concentration of DNA.
其它相關店家資訊