0972064
喬智生技-實驗室規劃,實驗室耗材批發,台中實驗室規劃,台中實驗室耗材批發
店家商品
Application
CO2 Incubator is widely used in modern medicine, biology, chemistry and agriculture science for the culture of biological cells, tissues and bacterial.
Features
Faster CO2 concentration restoration speed
If the door needs to be opened frequently during the experiment, infrared sensors are the best choice.
The imported infrared (IR) sensor has the characteristics of fast monitoring of carbon dioxide gas and is not affected by fluctuations in external temperature and humidity.
Internal circulation system
Adopts high-quality fan, higher ventilation efficiency and better temperature uniformity.
The circulation fan speed can be automatically controlled.
High cleanliness level
The door temperature controller can effectively prevent condensation on the glass door of the incubator and prevent the possibility of microbial contamination caused by condensation water from the glass door.
The CO2 air inlet is equipped with a high-efficiency microbial filter. For particles with a diameter of 0.3μm or greater, the filtration efficiency is as high as 99.99%, effectively filtering bacteria and dust particles in CO2 gas.
HEPA high-efficiency filter can effectively filter out bacteria and dust particles in the outside air, keeping the incubator in a sterile state.
Humanized design
Two-layer stacking makes full use of laboratory space.
Large-screen LCD display, microcomputer PID control and can simultaneously display temperature, CO2 concentration, relative humidity and operation, fault prompts, etc.;
The menu-based operation is simple and easy to understand and facilitate observation and use.
Safety
With temperature limit alarm system and visible& audible alarm system.
Low temperature, high temperature and over-temperature alarms, CO2 too high or too low concentration alarms.
Safety facilities such as alarms if the door is opened for too long and UV sterilization working status reminders.
Model | ICB-CO2-40Y | ICB-CO2-80Y | ICB-CO2-150Y | ICB-CO2-190Y | ICB-CO2-240Y | |
Capacity(L) | 40 | 80 | 155 | 190 | 240 | |
Circulation Mode | Forced convection | |||||
Dimension
(W*D*H) |
Internal (mm) | 400*286*350 | 400*450*500 | 480*530*610 | 520*530*690 | 600*630*670 |
External (mm) | 590*440*576 | 590*687*790 | 670*767*880 | 708*710*1030 | 788*837*940 | |
Temperature | Range (℃) | RT.+5~55 | ||||
Fluctuation (℃) | ±0.1 | |||||
Resolution (℃) | ±0.1 | |||||
Uniformity (℃) | ±0.3°C (37℃) | |||||
Recovery | (Door open 30s, recovery to 37℃ ≤ 8min | |||||
Humidity | Range | >90% | ||||
Method | Natural vaporization | |||||
CO2 | Range | 0~20% | ||||
Resolution | +0.1% | |||||
Sensor | IR sensor | |||||
Recovery | (Door open 30s, recovery to 5%)≤3min | |||||
Heating Method | Air-jacketed, PID Control | |||||
Display | LCD | |||||
Material | Internal | 304 Stainless steel | ||||
External | Cold rolled steel | |||||
Shelves(Standard / Max ) | 2/4 | 2/4 | 3/6 | 3/6 | 3/6 | |
Test Hole (mm) | φ25 | |||||
Safety Device |
Temperature limit alarm, visible& audible alarm,
Low temperature, high temperature and over-temperature alarms, CO2 too high or too low concentration alarms, Alarm for long door opening time, UV sterilization working status reminder |
|||||
Sterilization Method | 90℃ high-temperature moist heat sterilization+UV Sterilization | |||||
Electricity |
Voltage/
Frequency |
AC 220/110V, 50/60Hz | ||||
Consumption (W) | 350 | 500 | 750 | 750 | 950 | |
N.W./G.W. (kg) | 50/70 | 64/90 | 85/112 | 90/134 | 95/148 | |
Shipping Dimension
(W*D*H) (mm) |
650*710*740 | 750*710*960 | 840*790*1070 | 830*840*1300 | 960*900*1160 | |
Optional |
1. RS485/232 interface and communication software
2. Special CO2 pressure reducing valve 3. Humidity display system |